Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V3.4.0.14
-
Fix Version/s: V3.4.0.15
-
Component/s: None
-
Labels:None
-
Account:SPC EthernetIp Slave (SPCETHERNE)
Description
Valid range for assembly numbers is 1 - 8000FFFF according to manual.
This is not checked in the set-config packet, nor is it checked during EIP_OBJECT_AS_REGISTER_REQ. Such checks should be added.
Furthermore: Equal assembly instance numbers for input/output should be rejected as well.
Presumably, this will only be done for the future minor release as we should avoid changes at API level.
Attachments
Issue Links
- clones
-
PSEIP-116 Add checks for valid assembly instance numbers
- Closed