Uploaded image for project: 'EtherNet/IP Firmware V3'
  1. EtherNet/IP Firmware V3
  2. PSEISV3-47

Attribute 1 (Interface speed) of Ethernet Link Object is incorrectly handled on LinkDown

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.1.0.0
    • Fix Version/s: V3.1.0.1, V3.1.1.0, V3.2.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      Attribute 1 (Interface speed) of Ethernet Link Object (Class 0xF6, instance 0 (port0) and 1 (port1)) is not cleared when link of the port is lost.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: