Uploaded image for project: 'EtherNet/IP Firmware V3'
  1. EtherNet/IP Firmware V3
  2. PSEISV3-463

Writing to attribute 6 of TCP/IP Interface object is rejected with unexpected status code

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.0.10
    • Fix Version/s: V3.4.0.11
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      During the CT15 test run, attribute 6 of the TCP/IP Interface object is written with value [01 00 54], which is invalid data since the string has to be padded.
      The test tool expects error code 0x13 "not enough data". The firmware returns error code 0x09 "Invalid attribute value".

      The firmware shall be corrrected to reject the service with the error code 0x13.