Get_Attributes_All response at class level shall deliver data up to and including the last implemented attribute in the range [1, 2, 6, 7]

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.0.7, V3.4.2.0
    • Fix Version/s: V3.4.0.8, V3.4.3.0 , V3.5.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      If the "last" attribute (recursively) in the range is disabled, it should not be delivered.