Uploaded image for project: 'EtherNet/IP Firmware V3'
  1. EtherNet/IP Firmware V3
  2. PSEISV3-407

Size of remanently stored string-type attributes is not updated when loaded from flash

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.2.0
    • Fix Version/s: V3.4.3.0 , V3.5.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      If an attribute of type STRING or SHORT_STRING (e.g. Interface label, Product Name, Host Name, Domain Name) is loaded from the remannet data storage in flash memory, the attribute size is not updated and thus, excess garbage bytes or insufficient bytes may be delivered when the attribute is retrieved over the network via the GET_ATTRIBUTE_SINGLE service.
       