Still insufficient number of members (== partitions in DPM I/O area) available

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.0.3, V3.4.1.0
    • Fix Version/s: V3.4.0.4, V3.4.1.0, V3.5.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      First patch done with PSEISV3-337 did not fix the issue. Next to usMaxMember parameter of assembly object, we need ot increase the usMaxInstance attribute of the CIP_IO object accordingly.