Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V3.3.0.13, V3.3.0.14
-
Fix Version/s: V3.3.0.15
-
Component/s: None
-
Labels:None
-
Account:SPC EthernetIp Slave (SPCETHERNE)
Description
During the test run, one of the class3 CIP services is not answered.
This is what the test case does:
- Open 2 Class 3 connections to the DUT over each of the 3 host IP addresses:
- Get Attribute Single command to attributes 2 and 3 of instance 1 of the Identity Object.
- 100 msec RPI
- Make sure all connections were established.
- Sustain the messaging for a period of 2 minutes, watching for connection failures or message timeouts.
- Send a UCMM message to attribute 4 of the Identity Object every 500 msec rotating through the 3 host IP addresses.
- Verify that the data returned on all message responses matches the Identity information settings configured for the DUT.
- Close all Class 3 connections.
Attachments
Issue Links
- relates to
-
PSEISV3-277 EDITT Test P9.3 fails due to missing CIP service response (EDITT V1.23)
- Closed