Uploaded image for project: 'EtherNet/IP Firmware V3'
  1. EtherNet/IP Firmware V3
  2. PSEISV3-306

Opening an InputOnly connection corrupts frames of already running ExclusiveOwner connection

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.3.2.0
    • Fix Version/s: V3.4.0.0, V3.4.1.0, V3.5.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      Opening an InputOnly connection corrupts frames of already running ExclusiveOwner connection.

      The condition is that the InputOnly connection address the same T2O connection point that is used by t he  Exclusive Owner connection.

      This corrupts the length field within the connected data item of the sent IO frames.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  KMichel Kai Michel
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: