Uploaded image for project: 'EtherNet/IP Firmware V3'
  1. EtherNet/IP Firmware V3
  2. PSEISV3-134

Unknown Identity Status after Channel Init

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.3.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      After Channel Init and before a cyclic connection is established, Status attribute of Identity object has sometimes the value 0x0004 (Configured, Extended Device Status = "Self-Testing or Unknown").

      Expected 0x0034 (Configured, Extended Device Status = "No I/O connections established").

      Class 0x01, instance 1, attribute 5.
      Device was configured by config.nxd.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    KMichel Kai Michel
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: