Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V2.13.0.6
-
Fix Version/s: V2.13.0.13
-
Component/s: Firmware
-
Labels:None
-
Account:SPC EthernetIp Slave (SPCETHERNE)
Description
If the Ethernet Link instance is configured to forced settings (10/100MBits Full/Half Duplex) and the instance has no active link, attribute 2 reports status "Auto-negotiation in progress".
Expected status is: "Auto-negotiation not attempted".
Attachments
Issue Links
- blocks
-
PSEIPCORE-205 Ethernet Link Object attribute 2: wrong autonegotiation status in case of no link
- Closed
-
PSEIS-933 Update to EtherNet/IP Core V2.4.0.17