EIP_OBJECT_CYCLIC_EVENT_IND overflows object task's message queue

    Details

    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      If stress is put on the device by means of a class 1 connection with the following parameters:

      1 ms RPI in T->O direction
      500 ms RPI in O->T direction
      512x timeout multiplier

      And in parallel, you hammer the target with unconnected GetAttributeSingle requests for e.g. EThernetLink, instance 1, attribute 5

      then the object task's packet queue will be overflown with command 0x1ae0 (EIP_OBJECT_CYCLIC_EVENT_IND) within a few minutes. If the queue is full, cyclic communication stops suddenly.
       

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description