Uploaded image for project: 'EtherNet/IP Adapter V2'
  1. EtherNet/IP Adapter V2
  2. PSEIS-823

"Controlled by application" start of bus communication setting from configuration database is not always applied after channel init

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.12.2.0, V2.13.0.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      Controlled by application start of bus communication setting from the configuration database file is not applied after channel init, if stack BUS ON flag was set previously. According to Dual-Port Memory Interface Manual, Revision 12, 2012-03, EN, page 132 on Channel Init the firmware should read and evaluate the configuration settings or SYCON.net database again.