Uploaded image for project: 'EtherNet/IP Adapter V2'
  1. EtherNet/IP Adapter V2
  2. PSEIS-733

Stack cannot be reconfigured when "duplicate IP address" error occurred (database configuration only)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.10.0.0, V2.11.0.0
    • Fix Version/s: V2.10.5.0, V2.11.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      In case there is a duplicate IP address configured using Sycon.NET, the device will detect this and indicates the error via the communication error (DPM and the network and module LEDs. If then the IP address is changed in Sycon.NET in order to solve the IP address conflict and the configuration is downloaded again this will not solve the error state.
      The device does not detect any communication error, but remains without communication settings.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  KMichel Kai Michel
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: