Uploaded image for project: 'EtherNet/IP Adapter V2'
  1. EtherNet/IP Adapter V2
  2. PSEIS-686

Get Firmware Parameter request returns wrong parameter value

    Details

    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      When sending the packet RCX_GET_FW_PARAMETER_REQ (0x2F88) with ulParameterID set to PID_EIP_IP_CONFIGCONTROL (0x3000A002), the confirmation packet always holds value 0 (PRM_CFGCTRL_STORED_CFG).
      Actually the current configuration method (PRM_CFGCTRL_DHCP, PRM_CFGCTRL_BOOTP or PRM_CFGCTRL_FIXIP) should be returned.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  KMichel Kai Michel
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: