Feature: Support new parameter "Admin State" (Ethernet Link Object) in packet EIP_APS_SET_CONFIGURATION_PARAMETERS_REQ (0x00003612)

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.9.2.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      The current EtherNet/IP stack now supports attribute 9 (Admin State) of the Ethernet Link Object (class ID 0xF6). This attribute must be stored in remanent memory. Therefore, this parameter must be configurable via the packet EIP_APS_SET_CONFIGURATION_PARAMETERS_REQ (0x00003612).