Uploaded image for project: 'EtherNet/IP Adapter V2'
  1. EtherNet/IP Adapter V2
  2. PSEIS-450

AP-Task must not configure PHYs upon receiption of TCP Set_Config packet (0x200) in case Quick Connect is enabled

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.8.3.0
    • Fix Version/s: V2.9.1.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      In case that QuickConnect is enabled, the AP-Task configures the PHYs when the packet 0x200 is received.
      This delays the startup process by about 50ms, which is not tolerable.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  KMichel Kai Michel
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: