Uploaded image for project: 'EtherNet/IP Adapter V2'
  1. EtherNet/IP Adapter V2
  2. PSEIS-416

Stack uses vendor specific error 0x320 when addressing assemblies incorrectly in an incoming ForwardOpen

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.7.7.0
    • Fix Version/s: V2.9.1.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      If a connection originator tries to open a connection to the device with the consuming and producing connection points reversed (which would be invalid), the device returns a vendor specific error code 0x320.

      This error code can be replaced by an error code defined in the specification:

      0x012A: INVALID CONSUMING APPLICATION PATH
      0x012B: INVALID PRODUCING APPLICATION PATH

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    KMichel Kai Michel
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: