Uploaded image for project: 'EtherNet/IP Core V2'
  1. EtherNet/IP Core V2
  2. PSEIPCORE-277

Extended Device Status (attribut 5) of Identity object might indicate wrong status

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.5.0.0
    • Fix Version/s: V2.5.0.7
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      In case the device consumes assembly data that does not hold a run/idle header information, the extended device status field of the Identity object attribute 5 might indicate a wrong status.

       

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description