Details
-
Type: New Feature
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: V2.5.3.0
-
Labels:None
-
Account:SPC EthernetIp Core (SPCETHERNET)
Description
After sending an object change indication to the application, the stack expects that the response paket is received within 3 seconds. If it does not receive this packet within 3 seconds, it rejects the original SET-ATTRIBUTE service with status code 0x1E (Embedded service failed).
In case the host application stores remanent data, it might take more than 3 seconds to actually process the indication.
Therefore, this value shall be increased to 10 seconds.
Attachments
Issue Links
- relates to
-
PSEIPCORE-268 Timeout value for object change inidication packets shall be increased from 3 to 10 seconds