Timeout value for object change inidication packets shall be increased from 3 to 10 seconds

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.5.3.0
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      After sending an object change indication to the application, the stack expects that the response paket is received within 3 seconds. If it does not receive this packet within 3 seconds, it rejects the original SET-ATTRIBUTE service with status code 0x1E (Embedded service failed).

      In case the host application stores remanent data, it might take more than 3 seconds to actually process the indication.

      Therefore, this value shall be increased to 10 seconds.