Duplicate sequence numbers of class 0 process data frames are not detected.

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.4.0.0, V2.5.0.0
    • Fix Version/s: V2.5.2.0
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      In case of a class 0 connection, the device does not detect duplicate IO frames.

      The EtherNet/IP stack is supposed to monitor the sequence number of the encapsulation layer, that is sent along with each process data frame. Currently, a class 0 connection does not time out in case all process data frame holding the same sequence number.