Reported error by CT14:
> *** Point-Point T->O SockAddr Info item sin_port 2222 in the ForwardOpen response does not match the requested port 2000 in the ForwardOpen request.
Excerpt from test spec (attached => CIP_PCTS.pdf):
j) Point-Point T->O on non-default port test
This test verifies the the following statement in Vol 2 Ed 1.21 section 3-3.9.6:
"If the point-point consumer chooses a port number that is different than 0x08AE, then the
point-point consumer shall send a Sockaddr Info item indicating the chosen port number."
i. Open an I/O connection with Point-Point T->O on a UDP port other than 2222.
Fail: The DUT is unable to open the connection on the requested port.
ii. Continuously receive T->O I/O for 10 second on the selected port.
Pass: The DUT generates I/O on the selected port.
Fail: The DUT does not generate I/O or still generate I/O on the default port 2222.
iii.Close the I/O connection
Attachments
Issue Links
- relates to
-
PSEIS-811 Update to EtherNet/IP Core V2.3.0.5