Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V2.3.0.0
-
Labels:
-
Account:SPC EthernetIp Core (SPCETHERNET)
Description
The stack fails the T->O Multicast Matching Rules test (CT14). The following sub-tests are failing:
a) T->O RPI mismatch test
> *** The DUT returned unexpected success for T->O RPI mismatching, expected General Status 0x01, Extended Status 0x112!
b) T->O Network Connection Parameters size mismatch test
> *** The DUT returned unexpected success for T->O Size mismatching, expected General Status 0x01, Extended Status 0x134!
c) T->O Network Connection Parameters Fixed/Variable mismatch test
> *** The DUT returned unexpected success for T->O Fixed/Variable mismatching, expected General Status 0x01, Extended Status 0x135!
d) T->O Network Connection Parameters Priority mismatch test
> *** The DUT returned unexpected success for T->O Priority mismatching, expected General Status 0x01, Extended Status 0x136!
e) Transport Class mismatch test
> *** The DUT returned unexpected success for Transport Class mismatching, expected General Status 0x01, Extended Status 0x137!
f) T->O Production Trigger mismatch test
> *** The DUT returned unexpected success for T->O Production Trigger mismatching, expected General Status 0x01, Extended Status 0x138!
g) T->O Production Inhibit Time mismatch test
> *** The DUT returned unexpected success for T->O Production Inhibit mismatching, expected General Status 0x01, Extended Status 0x139!
More information can be found in the attached CIP Conformance Test Specification (PUB00166), chapter "6.3.5) T->O Multicast Matching Rules test on the same network interface"
Attachments
Issue Links
- relates to
-
PSEIS-811 Update to EtherNet/IP Core V2.3.0.5
- Closed