RCX_GET_SLAVE_CONN_INFO_REQ command succeeds if invalid slave handle is used

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.2.0.0
    • Fix Version/s: V2.2.0.1, V2.2.1.0
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      When scanner is configured, read slave connection information using a not existing handle (see packet below, ulHandle can be upto 0xFFFFFFFE).

      Firmware returns the information of the first configured slave.
      Expected an error (TLR_E_UNKNOWN_HANDLE?), when handle does not exist in the current configuration.