Uploaded image for project: 'EtherNet/IP Core V2'
  1. EtherNet/IP Core V2
  2. PSEIPCORE-105

Connection status is not reported correctly in attribute 5 of identity object (extended device status)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.1.0.0, V2.2.0.0
    • Fix Version/s: V2.1.0.4, V2.2.0.1, V2.2.1.0
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      If there is one IO connection running and this connection has the run/idle flag set to zero (signaling idle), attribtue 5 of the identity object still shows the status "At least one I/O connection in run mode" (value 6 within the extended device status).
      The expected value is 7 "At least one I/O connection established, all in idle mode".

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    KMichel Kai Michel
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: