Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.8.3.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      The TimeSync object previously was disabled after system start and had to be actively enabled by the host application at each configuration through EIP_OBJECT_MR_REGISTER_REQ with a certain option flag EIP_OBJECT_MR_REGISTER_OPTION_FLAGS_USE_OBJECT_PROVIDED_BY_STACK. This method is discontinued.

      Instead, the TimeSync object can be dynamically activated/deactivated through the packet API with EIP_OBJECT_PRM_ENABLE_TIMESYNC_OBJECT, substituting the old method.

       

      This change affects applications that used the TimeSync object in previous firmware versions.

      Applications that activated the TimeSync object using EIP_OBJECT_MR_REGISTER_REQ have to remove this command and instead must enable the TimeSync object through the new parameter.

      Applications that have not used the TimeSync object before are not affected.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    MBommert Marc Bommert
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: