Uploaded image for project: 'EtherNet/IP Core V3'
  1. EtherNet/IP Core V3
  2. PSEIP-551

Allow enabling of TimeSync object attributes 16 and 17 (Priorities)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.7.3.0
    • Component/s: Core
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      We do not implement any logic here and have these attributes disabled by default.
      The host application can however enable them and take control of the attribute values and behavior. Due to a bug, enabling these attributes was always rejected. This should be fixed.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MBommert Marc Bommert
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: