[SCANNER] Implement master status block

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.7.3.0
    • Component/s: ScannerAP
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      The scanner V3 shall implement the following fields inside the DPM Master Status Block:

      • ulSlaveState (common slave state)
      • ulNumOfConfigSlaves (number of configured slaves)
      • ulNumOfActiveSlaves (number of active slaves, i.e. connection running)
      • ulNumOfDiagSlaves (number of slaves reporting diagnostic issues)

      The slave state shall be "undefined" during initialization and reset. In bus on mode, the slave state shall be "failed" in case a connection is missing or one slave reports diagnostic information. In case all configured connections are running, slave state shall be "ok".