Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.7.0.0
    • Fix Version/s: V3.7.0.4, V3.7.2.0
    • Component/s: Core
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      Currently the LLDP Management Object instance 0 attribute 2 (LLDP transmission period) can be configured in a range from 5 to 32768. This results in an unexpected error reported by new CT 18.1.0.10 (rev CT19 internal).

      According to 802.1AB-2016, the maximum allowed transmit interval shall be 3600 seconds.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    TBaranczyk Thomas Baranczyk
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: