Details
Description
1. Configure device (EIP_APS_SET_CONFIGURATION_PARAMETERS_REQ) and create object Time Sync 0x43 (EIP_OBJECT_MR_REGISTER_REQ).
See attached text file for packet data.
2. From CIFX EIM send service Get Attribute List for Time Sync object (EIP_OBJECT_UNCONNECT_MESSAGE_REQ).
Response from device (frames 9 and 14) contain 0 values for most attributes and the data structure seems to be wrong (Wireshark shows 21 of 29 attributes).
3. Read all Time Sync attributes by service Get Attribute Single from Hilscher EtherNet/IP Tool.
4. From CIFX EIM send service Get Attribute List for Time Sync object.
Response from device (frame 699) contains valid values for all 29 attributes.
5. From CIFX EIM send again service Get Attribute List for Time Sync object.
Response from device (frame 702) contains the same values, expected different values for time attributes 3 and 4.
6. Read Time Sync attributes 1-7 by service Get Attribute Single from Hilscher EtherNet/IP Tool.
7. From CIFX EIM send service Get Attribute List for Time Sync object.
Response from device (frame 879) contains new values, for time attributes 3 and 4.