Fail of manual TTL test: "Routing to existent Default Gateway Behavior, TTL = 2"

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.5.0.0
    • Component/s: Core
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      Attribute 8 of TCP/IP Interface object is configured to value 2.

      In case the originator is located in another subnet and tries to open a multicast connection to the DUT, the DUT rejects that connection with extended status 0x813, which is defined as:

      "A multicast connection has been requested between a producer and a consumer that are on different subnets, and the producer is not configured for off-subnet multicast."

      The DUT is supposed to accept the connection.