Uploaded image for project: 'EtherNet/IP Core V3'
  1. EtherNet/IP Core V3
  2. PSEIP-138

Missing some attribute value validation checks

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.5.0.7, V3.6.0.0
    • Fix Version/s: V3.5.0.8, V3.6.0.1, V3.6.1.0, V3.7.0.0
    • Component/s: Core
    • Labels:
      None
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      Identity Attribute 3: Data size is not checked. Two bytes are expected. Lower or higher data sizes should be rejected and are currently not.

      Identity Attribute 7: CIp short string minimum length is 1 byte. This is not checked currently. Only the upper limit is checked and rejected if too much data is provided.

      EthernetLink attribute 9: Data size of zero is not rejected with CONFIG_TOO_SMALL status

       

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MBommert Marc Bommert
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: