[CIP Sync] Time Sync object attribute 27 does not behave correctly (certification issue)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.5.0.6, V3.5.3.0
    • Fix Version/s: V3.5.0.7, V3.6.0.0
    • Component/s: None
    • Labels:
    • Account:
      SPC EthernetIp Core (SPCETHERNET)

      Description

      CIP attribute 27 (Steps Removed) of the Time Sync object has 0 as its default value. However, in case a valid PTP clock master detected, this value must be unequal to 0, which is not the case. Currently, attribtue 27 is always 0.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    KMichel Kai Michel
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated: