Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: V3.9.0.0
-
Component/s: None
-
Labels:None
-
Account:SPC EthernetIp Core (SPCETHERNET)
Description
To ensure consistency, the EIP_OBJECT_CL3_SERVICE_IND generated in response to a service request directed at a user object previously registered with EIP_OBJECT_MR_REGISTER_REQ is now subject to a 3-second timeout. If the timeout expires, the request will be replied to with an error. Previously, no explicit timeout did apply on such indications.
This update enforces a maximum response time for the host application, ensuring that the processing time for all explicit services on the application side remains within a reliable and predictable range. This time limit should be significantly lower than the three second timeout value.