Uploaded image for project: 'EtherNet/IP Scanner'
  1. EtherNet/IP Scanner
  2. PSEIM-624

Unexpected communication state STOP after ACD conflict

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V2.11.2.0, V2.12.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      In case the EtherNet/IP scanner device is configured and connected to the network where another device has the same IP address, the communication state changes to STOP (0x02).

      The state shall be IDLE or OPERATE, as the bus on state remains unchanged.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  TBaranczyk Thomas Baranczyk
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: