Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V2.10.0.0
-
Fix Version/s: V2.10.0.11, V2.11.0.1, V2.11.1.0, V2.12.0.0
-
Component/s: None
-
Labels:None
-
Account:SPC EthernetIp Master (SPCETHERNETMA)
Description
When opening an unlimited number of class 3 connections, for the first connections the device answers nicely, but when the maximum number of connections (64) is exhausted, then the requests are not correctly answered with an error code, but are still answered with the success error code in a (according to wireshark) malformed packet.