Uploaded image for project: 'EtherNet/IP Scanner'
  1. EtherNet/IP Scanner
  2. PSEIM-581

Exceeded maximum number of connections: Further forward open requests not properly rejected

    Details

    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      When opening an unlimited number of class 3 connections, for the first connections the device answers nicely, but when the maximum number of connections (64) is exhausted, then the requests are not correctly answered with an error code, but are still answered with the success error code in a (according to wireshark) malformed packet.
       

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  KMichel Kai Michel
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: