CT15: Request over class 3 with same sequence count needs to trigger (re)production of the previous response (certification issue)

    Details

    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      These requirements were not tested previously by the Conformance Test, but are now part of CT15.

      According to specification Vol1. Figure 3-4.5, reception of UnitData with the same sequence count value should retrigger sending the response to the previous request (the one which initally had that particular sequence count value), instead of being dispatched towards the message router towards the object dictionary.