Uploaded image for project: 'EtherNet/IP Scanner'
  1. EtherNet/IP Scanner
  2. PSEIM-533

Get_Attributes_All response of TCP/IP Interface object 0xF5 holds wrong default data for attribute 9 (Mcast Config) in case attribtue 9 is not activated

    Details

    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      Get_Attributes_All response of TCP/IP Interface object 0xF5 holds wrong default data for attribute 9 (Mcast Config) in case attribtue 9 is not activated.

      Default is all zero.

      The issue shows up during the CT14 run of the TCP/IP Interface object test. It is declared as a warning, and therefore will not lead to a fail of the certification process.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    KMichel Kai Michel
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: