Uploaded image for project: 'EtherNet/IP Scanner'
  1. EtherNet/IP Scanner
  2. PSEIM-507

PHY default configuration is not applied

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.9.1.0
    • Fix Version/s: V2.9.2.0, V2.10.0.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      PHY1 is not enabled in test DLR setup.

      This bug will only take effect if the PHY remains in default config, i.e. if it is not subsequently (re-)intialized by other means (e.g. via a database). All target platforms are affected.

      Solution: To be fixed in the stack by calling Drv_PhyInitialize() during late Stack initialization, i.e. IntializeSystem() in Config.c

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MBommert Marc Bommert
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: