Uploaded image for project: 'EtherNet/IP Scanner'
  1. EtherNet/IP Scanner
  2. PSEIM-344

Stack shall reject set services to tcp object attribute 3 and 5 when hardware switch settings are active

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.4.0
    • Fix Version/s: V2.6.5.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      Attribute 3 (configuration control) hold information about how the device shall obtains its IP address.

      Attribute 5 (interface configuration) holds the IP address information.

      Both attributes usually can be set via an CIP service (set attribute single).
      in case that the configuration is set via an hardware switch (and thus is fixed),
      these attribute shall not be settable. When trying to set theses attribute general status code 0x0C (Object State Conflict) shall be returned.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  KMichel Kai Michel
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: