Uploaded image for project: 'EtherNet/IP Scanner'
  1. EtherNet/IP Scanner
  2. PSEIM-343

Tcp Interface attribute 3 shall not be settable by the host application

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.4.0
    • Fix Version/s: V2.6.5.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      Attribute 3 holds the config control value which decides how to obtain the device's IP address.
      This attribute is updated automatically by the stack when the host application sends the command TCPIP_IP_CMD_SET_CONFIG_REQ (0x00000200).
      So this attribute shall only be writable by services comming from the netwok, not by services comming internally from the host application.