Setting of tcp object attribute 5 only allowed when SNN is set to default for CIP safety devices

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.4.0
    • Fix Version/s: V2.6.5.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      When operating as CIP safety device and the SNN (safety network number) is NOT set to its default value (all bytes set to 0xFF) the set service to the tcp interface object attribute 5 shall be rejected.