Uploaded image for project: 'EtherNet/IP Scanner'
  1. EtherNet/IP Scanner
  2. PSEIM-330

ReOpened: EIP_OBJECT_FWD_OPEN_FWD_COMPLETION_IND provides wrong connection serial number

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.4.0
    • Fix Version/s: V2.6.5.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      If the device is target and the connection could be established, the indication EIP_OBJECT_FWD_OPEN_FWD_COMPLETION_IND provides the wrong connection serial number.
      The target connection serial number is provided, instead of the originator connection serial number.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  KMichel Kai Michel
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: