Command EIP_OBJECT_RESET_REQ accepts wrong parameter values

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.4.9.1
    • Fix Version/s: V2.7.1.0
    • Component/s: Firmware
    • Labels:
      None
    • Sprint:
      ODVA - 2014 KW 07
    • Account:
      SPC EthernetIp Master (SPCETHERNETMA)

      Description

      The command accepts all values 0-0xFFFFFFFF for parameter ulResetMode, but allowed is 0-2. Same problem with ulDataIdx. Furthermore, the command should perform a reset of EtherNet/IP adapter(s) via the network. But the command only resets the scanner, independent from parameters.