Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: V5.3.0.19(open), V5.4.0.15(open), V5.5.0.1, V5.5.1.0 (open)
-
Component/s: None
-
Labels:
-
Account:SPC EtherCat Slave (SPCETHERCA)
Description
DC syncmonitoring does not work correctly. Results in missing error code and rejecting the switch to safeop.
The DC Conformance testcase fails as result.
Attachments
Issue Links
- consists of
-
PSECSV5-702 DC sync monitoring requires updating the local time and resetting the timeout value
-