Explicit Device ID by Rotaryswitch value 0 handling changed, reason Conformance test record change [certification issue]

    Details

    • Account:
      SPC EtherCat Slave (SPCETHERCA)

      Description

      Explicit Device ID by Rotaryswitch set to Null changed meaning through Conformance test record. Now value 0 is used in testcase #91 despite ETG1020 says 0 is not valid.
      See Function: Task_EcatEsm_HandleDeviceIdent()
      But now a new mechanism for switchin on / Off the ID-Value is needed