Uploaded image for project: 'EtherCAT Slave V4'
  1. EtherCAT Slave V4
  2. PSECSV4-198

Master receives CoE packet with duplicated counter in CTT if only Inputs are configured

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.3.13.0
    • Fix Version/s: V4.3.19.0, V4.4.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EtherCat Slave (SPCETHERCA)

      Description

      Master receives CoE packet with dublicated counter in CTT. This happens because Syncmanager is switched off in HAL as a result of intentionally wrong configuration through Conformance Test Tool. ( CTT1.20.80, Test 1200 #45) So the memory area is not protected by Syncmanager any more and the data can be read by master.
      Took out the checks in HAL which switch off the Syncmanagers if thier configured memory areas (0x1000,0x1080,0x1100,0x1D00) ovelap.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  JKollmannsperger Jochen Kollmannsperger
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: