Uploaded image for project: 'EtherCAT Slave V4'
  1. EtherCAT Slave V4
  2. PSECSV4-1112

DC sync monitor crashes firmware when switching to OP in DC mode

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V4.10.0.2, V4.10.1.0(open)
    • Component/s: None
    • Labels:
      None

      Description

      DC sync monitor crashes firmware. The change which was made long time ago with PSECSV4-1030 (rev.103725) resulted in usage of internal bool variable instead of "unsigned int". Apparently this produces incompatibility when using rcx RTOS internal "interlocked_exchange" function.