Uploaded image for project: 'EtherCAT Master'
  1. EtherCAT Master
  2. PSECM-244

V3.0.X: possible crash when defect frames received (but CRC ok)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.6.0
    • Fix Version/s: V3.0.8.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC EtherCat Master (SPCETHERCATMA)

      Description

      The master trusts the received frames (when CRC is ok) and uses length values from frame for memcpy and other evaluation. This causes trouble when the length information is wrong. Too long memcpy overwrites management information.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  Ulli J Ulli J (Inactive)
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: