Uploaded image for project: 'Driver Ethernet'
  1. Driver Ethernet
  2. PSDRVETH-21

Implement switch counter diagnostics according profinet specification

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.0.0.0, V1.1.0.0
    • Fix Version/s: V1.1.3.0
    • Component/s: Core, PnD Switch Adapter
    • Labels:
      None
    • Sprint:
      PI Sprint KW 38/39 2015
    • Account:
      SPC Driver Ethernet (SPCDRIVERE)

      Description

      According Profinet Topology engineering guideline the following behavior is to be implemented for the switch counter statistics of the ports and interface

      • every frame sent by applications not aware of the physical ports (IP, Profinet RT, DCP) using automatic routing (bPortmask == 0) shall be counted as Output Packet of the interface
      • every frame received by the switch not beeing a peer to peer frame shall be counted as Input Packet of the interface
      • In automatic routing mode, the adapter shall not send packets on ports with link down. Otherwise the xpec switch counters of that port will change which is not allowed
      • Frames forwarded by the XC to a link down port shall not be counted in any of the counters, or the counters should be corrected. This probably requires changes to the XC code as well.