Uploaded image for project: 'PROFIBUS Slave'
  1. PROFIBUS Slave
  2. PSDPS-422

WRMSTRT_FLG_NO_ALARM_SUPP requires Alarm_Sequence_Mode_Count=32

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.4.0
    • Fix Version/s: V2.7.9.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profibus Slave (SPCPROFIBUSSL)

      Description

      Disabling alarm support, the sequence mode count is set to 32 which is not intuitive, expected is mode count of 0.
      The GSD parameter Alarm_Sequenc_Mode_Count defaults to 0 if not explicitly set to 32. So if no alarms are supported the optional GSD parameter is required.